<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">ivm</journal-id><journal-title-group><journal-title xml:lang="ru">Международный вестник ветеринарии</journal-title><trans-title-group xml:lang="en"><trans-title>International Journal of Veterinary Medicine</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2072-2419</issn><publisher><publisher-name>SpbGUVM Publishing House</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.52419/issn2072-2419.2024.2.393</article-id><article-id custom-type="elpub" pub-id-type="custom">ivm-1412</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>НЕЗАРАЗНЫЕ БОЛЕЗНИ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>NON-COMMUNICABLE DISEASE</subject></subj-group></article-categories><title-group><article-title>Характеристики электромагнитного излучения ветеринарного физиотерапевтического прибора УМИ-05-В</article-title><trans-title-group xml:lang="en"><trans-title>Characteristics of electromagnetic radiation of the veterinary physiotherapy device UMI-05-V</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Чуваев</surname><given-names>И. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Chuvaev</surname><given-names>I. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>канд. биол. наук, гл. ветеринар. врач клиники </p></bio><bio xml:lang="en"><p>PhD in Biological Sciences, Chief Veterinary Officer of Clinic </p></bio><email xlink:type="simple">virclin@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Будник</surname><given-names>Ж. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Вudnik</surname><given-names>Zh. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p> ст. ветеринар. врач клиники </p></bio><bio xml:lang="en"><p> Doctor of Veterinary Medicine of Clinic </p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Яшин</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Yashin</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>д-р ветеринар. наук, проф., проф. кафедры внутренних болезней животных им. А.В. Синева </p></bio><bio xml:lang="en"><p>Doctor of Veterinary Sciences, Professor, Professor of the Department of Internal Diseases of Animals named after A.V. Sinev </p></bio><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ООО «Институт Ветеринарной Биологии»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Institute of Veterinary Biology, Ltd.</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ФГБОУ ВО «Санкт-Петербургский государственный университет ветеринарной медицины»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Saint-Petersburg State University of Veterinary Medicine</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2024</year></pub-date><pub-date pub-type="epub"><day>28</day><month>06</month><year>2024</year></pub-date><volume>0</volume><issue>2</issue><fpage>393</fpage><lpage>399</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Чуваев И.В., Будник Ж.С., Яшин А.В., 2024</copyright-statement><copyright-year>2024</copyright-year><copyright-holder xml:lang="ru">Чуваев И.В., Будник Ж.С., Яшин А.В.</copyright-holder><copyright-holder xml:lang="en">Chuvaev I.V., Вudnik Z.S., Yashin A.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://vetjournal.spbguvm.ru/jour/article/view/1412">https://vetjournal.spbguvm.ru/jour/article/view/1412</self-uri><abstract><p>Изучены некоторые физические характеристики ветеринарного физиотерапевтического прибора УМИ – 05-В. С помощью милитесламетра ТПУ 02 определена магнитная индукция на разных уровнях мощности. Замер магнитной индукции проводили для каждого значения мощности. Зонд миллитесламетра размещали непосредственно на рабочей поверхности, в центре индуктора. Установлено, что минимальная магнитная индукция прибора составляет 350±6,0 мТл, а максимальная 1058±10,0 мТл. Во время работы устройства нагрев индуктора определялся с использованием тепловизора и секундомера. В течение рекомендуемого временного диапазона (10 минут) температура индуктора не превышала 46 ° С. Определение частоты импульсного излучения в зависимости от величины магнитной индукции проводили при помощи секундомера. На каждой рабочей мощности проводили подсчет количества импульсов за минуту и высчитывали количество импульсов в секунду (определение частоты). Выявлено, что УМИ-05-В является низкочастотным источником импульсного магнитного излучения с максимальной частотой 1.3 Гц при минимальной магнитной индукции 350±6,0 мТл и минимальной частотой 0.1 Гц при максимальной магнитной индукции 1058±10,0 мТл. При помощи линейки и миллитеслометра ТПУ 02 определена степень затухания магнитного импульса в зависимости от расстояния до рабочей поверхности УМИ – 05 – В. Зафиксировано, что величина магнитной индукции меняется обратно пропорционально расстоянию от индуктора. Изучена проникающая способность электромагнитного импульса через разные среды: биологические и не биологические при помощи милитесламетра ТПУ 02. Биологические ткани (мышечная, костная) и некоторые небиологические среды не влияют на прохождение электромагнитного импульса, в то время как сталь в значительной степени снижает прохождение импульса.</p></abstract><trans-abstract xml:lang="en"><p>We studied some physical characteristics of the veterinary physiotherapeutic device UMI-V-05. The magnetic induction at different power levels was determined using TPU 02 militeslameter. The magnetic induction was measured for each power value. The probe of the milliteslameter was placed directly on the working surface, in the center of the inductor. It was found that the minimum magnetic induction of the device is 350±6.0 mTl, and the maximum is 1058±10.0 mTl. During the device operation, the heating of the inductor was determined using a thermal imager and a stopwatch. During the recommended time range (10 minutes), the inductor temperature did not exceed 46 °C. Determination of the pulse radiation frequency depending on the magnetic induction value was carried out using a stopwatch. At each working power the number of pulses per minute was counted and the number of pulses per second was calculated (frequency determination). It was revealed that UMI-V-05 is a low-frequency source of pulsed magnetic radiation with the maximum frequency of 1.3 Hz at the minimum magnetic induction of 350±6.0 mTl and the minimum frequency of 0.1 Hz at the maximum magnetic induction of 1058±10.0 mTl. Using a ruler and a TPU 02 milliteslameter, the degree of magnetic pulse attenuation depending on the distance to the working surface of UMI-V-05 was determined, it was fixed that the value of magnetic induction varies inversely proportional to the distance from the inductor. The penetration ability of the electromagnetic pulse through different media: biological and non-biological using TPU 02 militeslameter was studied. Biological tissues (muscle, bone) and some nonbiological media (paper, glass, wood, polyethylene, water) do not affect the passage of the electromagnetic pulse, while steel significantly reduces the passage of the pulse.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>магнитотерапия</kwd><kwd>УМИ-05-В</kwd><kwd>импульсное магнитное поле</kwd></kwd-group><kwd-group xml:lang="en"><kwd>magnetic therapy</kwd><kwd>uroliths</kwd><kwd>UMI-V-05</kwd><kwd>pulsed magnetic field</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Максимов, А. В. Магнитная терапия в клинической практике / А. В. Максимов, В. В. Кирьянова // Физиотерапия, бальнеология и реабилитация. – 2019. – Т. 18. – № 6. – С. 412-426.</mixed-citation><mixed-citation xml:lang="en">Maksimov, A.V. Magnetic therapy in clinical practice / A.V. Maksimov, V. V. Kiryanova // Physiotherapy, balneology and rehabilitation. – 2019. – Vol. 18, No. 6. – pp. 412-426.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Чуваев И.В., Соколова О.А., Анализ использования низкочастотной импульсной магнитотерапии при лечении межпозвонкового остеохондроза у собак (клиническое исследование) // Актуальные вопросы ветеринарной биологии. – 2009. – № 3. – С. 22-27.</mixed-citation><mixed-citation xml:lang="en">Chuvaev I.V., Sokolova O.A., Analysis of the use of low-frequency pulsed magnetotherapy in the treatment of intervertebral osteochondrosis in dogs (clinical study) // Topical issues of veterinary biology. - 2009. – No. 3. – pp. 22-27.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Чуваев И.В., Дарков П.Ю., Будник Ж.С., Березина О.Н. Импульсная магнитотерапия при лечении мочекаменной болезни собак и кошек (клиническое исследование) // Актуальные вопросы ветеринарной биологии. – 2023. – № 3(59). – С. 64-71</mixed-citation><mixed-citation xml:lang="en">Chuvaev I.V., Darkov P.Yu., Budnik Zh.S., Berezina O.N. Pulsed magnetic therapy in the treatment of urolithiasis of dogs and cats (clinical study) // Topical issues of veterinary biology. – 2023. – № 3(59). – Pp. 64-71</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Улащик В.С. Магнитотерапия. Теоретические основы и практическое применение / В. С. Улащик, А. С. Плетнев, Н. В. Войченко, С. В. Плетнев ; под редакцией В. С. Улащик. — Минск: Белорусская наука, 2015. – 380 c.</mixed-citation><mixed-citation xml:lang="en">Ulashchik V.S. Magnetotherapy. Theoretical foundations and practical application / V. S. Ulashchik, A. S. Pletnev, N. V. Voychenko, S. V. Pletnev; edited by V. S. Ulashchik. – Minsk: Belarusian Science, 2015. — 380 p</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Золотухина Е.И., Улащик В.С. Основы импульсной магнитотерапии. - Витебск: Витебская областная типография, 2008. – 143 с.</mixed-citation><mixed-citation xml:lang="en">Zolotukhina E.I., Ulashchik V.S. Fundamentals of pulsed magnetotherapy. - Vitebsk: Vitebsk Regional Printing House, 2008. - 143 p.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Блынский Ф. Ю. автономная система для низкочастотной импульсной магнитотерапии / Ф. Ю. Блынский, А. В. Шкуратов // Вестник науки Сибири. – 2015. – № S1(15). – С. 137-142.</mixed-citation><mixed-citation xml:lang="en">Blynsky F. Yu. autonomous system for low-frequency pulsed magnetotherapy / F. Yu. Blynsky, A.V. Shkuratov // Bulletin of Science of Siberia. – 2015. – No. S1(15). – pp. 137-142.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Иванов,Д. В. Избранные вопросы магнитотерапии (краткий обзор литературы) / Д. В. Иванов, С. В. Токарева // Вестник новых медицинских технологий. Электронное издание. – 2021. – Т. 15, № 4. – С. 94-102.</mixed-citation><mixed-citation xml:lang="en">Ivanov, D. V. Selected issues of magnetotherapy (a brief review of the literature) / D. V. Ivanov, S. V. Tokareva // Bulletin of new medical technologies. Electronic edition. - 2021. – Vol. 15, No. 4. – pp. 94-102.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
